3. Town and City Centres
3.1 Where the Service Provider is replacing Lighting Points in those areas of the Project Network identified in column 1 of Table 1.5 below, the Service Provider shall ensure that:
3.1.1 Lighting Points of the corresponding [Lighting Class] identified in column 2 of Table 1.5 are placed in such relevant areas of the Project Network;
3.1.2 all Luminaires shall have a luminous intensity class of G4 or greater; and
3.1.3 light sources shall have a colour-rendering index equal to or in excess of Ra80.
Table 1.5 - Town and City Centres
Areas of the Project Network | [Lighting Class] |
Town and city centres which are mixed vehicular and pedestrian areas | CE1 |
Town and city centres which are wholly pedestrian areas | CE2 |
Town and city centres which are pedestrian subway areas | CE0 |
All other pedestrian subway areas on the Project Network | CE2 |