Town centre areas
The lighting requirements for lighting in town centre areas are detailed in this section.
Type of Traffic | Lighting class | ||||
Normal a Traffic Flow | High Traffic Flow | ||||
Ra Value | E3 | E4 b | E3 | E4 | |
Pedestrian only | Ra≥60 | CE4 | CE3 | CE3 | CE2 |
Mixed vehicle and pedestrian with separate footways | Ra≥60 | CE3 | CE2 | CE2 | CE2 |
a For the purpose of light level assessment all town centre areas in [***] shall be deemed as having normal traffic flow's unless specified otherwise in Appendix D (Project Specific Design Parameters) of this Output Specification.
B For the purposes of light level assessment all town centre areas in [***] shall be deemed as being in an E4 environmental zone unless specified otherwise in Appendix D (Project Specific Design Parameters) of this Output Specification.