District centre areas

The lighting requirements for lighting in district centre areas are detailed in this section.

Type of Traffic

 

Lighting class

 

 

Normal a Traffic Flow

High Traffic Flow

 

Ra Value

E3

E4 b

E3

E4

Pedestrian only

Ra≥60

CE5

CE4

CE3

CE2

Mixed vehicle and pedestrian with separate footways

Ra≥60

CE4

CE3

CE2

CE2

a  For the purpose of light level assessment all district centre areas in [***] shall be deemed as having normal traffic flow's unless specified otherwise in Appendix D (Project Specific Design Parameters) of this Output Specification.

B  For the purposes of light level assessment all district centre areas in [***] shall be deemed as being in an E4 environmental zone unless specified otherwise in Appendix D (Project Specific Design Parameters) of this Output Specification.