Sample sheet for an Apartment
Space Name | 1 Bed Apartment |
Data Sheet Reference | [ ]81 |
Primary Uses | Residential accommodation, comprising living room, kitchen, bathroom and bedroom together with any circulation and storage space as per the requirements set out in section 4.1.4 of the Output Specification. |
Potential Regular Occupancy | |
Minimum Space Requirement | 57m2 |
Minimum Height Requirement | Single storey |
Adjacency Requirements | To be served directly from residents secure access corridors. |
Heating Requirements | As section 7.1.9, Annex II and Contractors Proposals. Low surface temperature radiators to be used |
Ventilation Requirements | Natural Ventilation to living room and bedroom. Mechanical ventilation to kitchens and bathrooms as section 7.1.13, Annex II and Contractors Proposals. |
Power Requirements | As Annex V |
Lighting Requirements | To suit domestic environment and as Annex II and Contractors Proposals. |
Water Requirements | Potable water to kitchen and bathroom area Domestic connections as section 7.1.10, Annex II and Contractors Proposals with connections to suit kitchen/bathroom installations. All pipework to be insulated and concealed in a manner so as to isolate residents from high surface temperatures. |
Telecare Installations | As section 4.2.2m), Annex II and Contractors Proposals. |
Fire & Emergency Installations | As section 4.2.2e), Annex II and Contractors Proposals. |
Other Requirements | TV aerial point to living room and bedroom Kitchen installations as per section 7.1.6, Annex II and Contractors Proposals. Bathroom installations as per section7.1.7, Annex II and Contractors Proposals. |
Floor finishes | Kitchens/bathrooms to have waterproof, non-slip covering as Annex II and Contractors Proposals. Other areas are the responsibility of the tenant. |
Wall finishes | Plaster/paint or similar |
Ceiling finishes | Plaster/paint or similar |
Furniture | None |
Other Fixtures/Fittings | None |
____________________________________________________________________________________________
81 It is suggested that a referencing system is used.