G.4.3  Parameters to be Tested Monthly

Parameters to be tested monthly are as specified in Table G-1. However, if a Critical Parameter that is specified in Table G-1 for testing once per month is found to be greater than 95% of the allowed limit, the parameter shall thereafter be tested daily until it is less than 95% of the allowed limit, at which point it reverts back to monthly testing. If a Non-Critical Parameter that is specified in Table G-1 for testing once per month is found to be greater than 95% of the allowed limit, the parameter shall thereafter be tested bi-weekly until it is less than 95% of the allowed limit, at which point it reverts back to monthly testing.