Office Planning

private offices

- minimum of 10 sq.m.

- maximum of 30 sq.m.

semi-private offices (for 2 or more occupants)

- 14 sq.m. to 35 sq.m.

general office space (open plan)

- economical standard

6 sq.m./person

- reasonable average

7 sq.m./person

- liberal standard

9 sq.m./person

interior circulation (ingress and egress to work stations)

- corridors

1.50 to 3.0 m. wide

- main aisles

1.50 m. wide (substantial traffic areas to main exits)

- intermediate aisles

1.20. wide (moderate amount of traffic)

- secondary aisles

0.90 m. wide (between rows of desk)

conference room (for use by 15 people)

- 47sq.m.

- add approximately 0.9 sq.m. for each additional person to be provided for.

reception areas (for use by 15 people)

- 37 sq.m.

- add approximately 0.9 sq.m. for each additional person to be provided for.

waiting/interviewing room (for use by 15 people)

- 20 sq.m.

- add approximately 0.9 sq.m. for each additional person be provided for.

storage/filing rooms

- 5 % of total office area

finished ceiling height (average)

- 2.4 m. to 2.6 m.

floor to floor height (typical)

- 3.4 m. to 4.5 m.

elevators

- 1 unit for every 2,300 sq.m.

elevator lobbies

- 1.8 to 2.8 m. wide

- elevators on one side only

- 3.0 to 3.7 m. wide

- elevators on both sides